    Standing Seam Install Guide — Architectural: Image II, Vertical Seam, Snap-Lock 150

    Best Buy MetalsNRD reference

    Standing Seam Install Guide — Architectural: Image II, Vertical Seam, Snap-Lock 150 — Best Buy Metals (BBM), 2019.

    Source: Best Buy Metals (BBM) · · 2019

    • Best Buy Metals (BBM)
    • Installation & Repair
    • standing
    • seam
    • install
    • guide
    • architectural
    • image
    • vertical
    • snap-lock

    This browser does not display PDFs inline. The document is unchanged — download it or open it in a new tab with the buttons above.

    From the document

    General Information ………………………………………………………………………………………. 4 a. Notice b. Applicability c. Safety d. Material Handling and Storage e. Packaging f. Unloading g. Handling h. Storage Working With Metal ……………………………………………………………………………………….. 6 a. Cutting and Drilling b. Expansion and Contraction c. Oil-Canning d. Dissimilar Metals e. Chemically Treated Lumber f. Graphite Design Information ……………………………………………………………………………………….. 8 a. Planning b. Slope c. Substrate d. Underlayment e. Insulation, Vapor Retarders, & Air Barriers f. Ventilation Product Information ……………………………………………………………………………………… 10 a. Panel Description and Options b. Panel Fasteners c. Sealants d. Metal Flashings and Trim Installation Instructions …………………………………………………………………………………. 13 a. Tools and Accessories b. Underlayment Installation c. Panel Installation d. Installing Trim and Flashing Details Roof Protection and Repair ……………………………………………………………………………... 19 a. Roof Protection During Installation b. Roof Protection After Installation c. Finishes and Touchup d. Repairs to Roof Appendix I. II. III. Accessories Guide…………………………………………………………………………… 20-21 Flashings and Trim ………………………………………………………………………….. 22-23 Installation Details d. Eave Detail (flush style)…………………………………………………………….. 26 e. Eave Detail (with gutter)……………………………………………………………. 26 f. Gable Detail (extended drip edge style)………………………………………….. 27 g. Gable Detail (box style with zee closure)………………………………………… 27 h. Valley Detail…………………………………………………………………………. 28 i. Ridge and Hip Detail……………………………………………………………….. 28 k. Vented Ridge Detail (with perforated zee closure)……………………………… 29 Standing Seam - Architectural Install Guide l. Peak Detail ………………………………………………………………………….. 30 m. Endwall (Highwall) Detail …………………………………………………………...30 n. Low Wall (Chimney, Skylight) Detail ………………………………………………31 o. Sidewall Detail ……………………………………………………………………….31 p. Slope Transition Detail ……………………………………………………………...32 q. Gambrel Detail ……………………………………………………………………… 32 r. Pipe Penetration Detail …………………………………………………………….. 33 s. Curb Detail Series ………………………………………………………………….. 34 thru 36 Standing Seam - Architectural Install Guide 1. GENERAL INFORMATION a. Notice · This guide contains general design guidance and suggested application instructions and details for proper application of Best Buy Metals (BBM) metal roofing products. It is the responsibility of the installer to verify conformance of installation to applicable building code, safety, and insurance requirements. BBM assumes no responsibility for any problems which might arise as a result of improper installation or any personal injury or property damage that may occur with the product’s use. · Statements in this guide are provided in good faith with the expectation that a design professional be consulted prior to any job decisions being made. Projects should be engineered to conform to applicable building codes, regulations, and accepted industry practices. · Installing a metal roofing system is a skilled craft that requires considerable trade knowledge and experience. It is not the intent of this guide or BBM to train individuals in the skills required to properly install a metal roof system or to convey all the necessary trade or general construction knowledge required to properly and safely perform work on a roof. BBM does not guarantee and is not liable for the qualifications of the installer. ○ For additional information and resources pertaining to the installation of metal roofing materials, the following sources are recommended: a. SMACNA (Sheet Metal and Air Conditioning Contractors’ National Association) Architectural Sheet Metal Manual. (www.smacna.org) b. The NRCA (National Roofing Contractors Association) Roofing Manual: Metal Panel and SPF Roof Systems. (www.nrca.net) · It is the responsibility of the BBM customer, installer, and/or designer to ensure that the details meet particular building requirements to assure weathertightness. · This guide is intended to be used in conjunction with engineered shop drawings specific to an individual project (if applicable). Custom roof conditions and detailing are covered by engineered shop drawings for the specific project. In the event of a conflict between this guide and the engineered shop drawings, the engineered shop drawings will take precedence. · Contents in this guide are subject to change and revision without notice. Please contact BBM to verify that this manual is the most current copy available. b. Applicability · The metal roof system as described within this manual is classified as a standing seam metal roof panel. Panels are mechanically attached with hidden fasteners to a continuous solid substrate with an underlayment. The detailing and attachment methods described within this manual best reflect “steep sloped” sheet metal joinery considered a craft or trade. This type of detailing, with clean lines and hidden fasteners is desired for high performance in combination with visual appeal. c. Safety · There are potential hazards associated with the installation of a metal roof system. An experienced installer should recognize these hazards, be qualified to work with them, and be capable of providing safe work practices and equipment that minimize the risks of injury. Following are some warnings that should be considered when working with metal roofing. These may not cover all hazards, so the installer should take proper precaution to be prepared for working on roofs and handling metal. ○ OSHA (Occupational Safety and Health Administration): Obey OSHA regulations, particularly those related to roof construction, such as Title 29 Code of Federal, 1926 Subpart M, Fall Protection. For copies of OSHA regulations visit www.osha.gov . ○ Use fall protection and all appropriate safety equipment as agencies or jobsites require. ○ Avoid working on surfaces that are covered with moisture, frost, snow/ice, dust or other substance that may cause unsure footing. ○ Never walk on substrate, underlayment, or panels that are not properly secured in place.

    An excerpt from the opening of the document, reproduced here so it can be read and searched. Best Buy Metals (BBM) holds the rights to the full work. The complete document is above.

    Provenance · Obtained from publicly circulated copies; no ownership claimed; removal honored on request

    Every document here names its publisher. Documents were gathered from public circulation and are posted in good faith with attribution — no ownership is claimed, nothing is sold, and rights holders can have anything removed on request. Read the content notice

    More from Installation & Repair

    On the same shelf

    Manufacturer bulletinPDF · 2 pages · 174 KB

    GAF TAB-C 2015-31: Repairing Hail Damage to Granule-Surfaced Membranes

    GAF's commercial technical advisory bulletin on hail that scours granules off a granule-surfaced membrane: what to inspect for, when coating the membrane is an acceptable repair, and the Diamond Pledge guarantee question that follows a coating repair.

    GAFGAF Technical Services · 2015

    Manufacturer bulletinPDF · 2 pages · 239 KB

    GAF TAB-R-178: Mixing New and Aged Asphalt Shingles

    GAF's bulletin on whether new shingles can be used to repair an aged roof — it allows it when dimensions and exposure match, warns that a perfect color blend is "not likely," forbids trimming shingles to match, and notes aged shingles crack during repair. Central to matching disputes.

    GAFGAF Residential Consumer Services · 2025

    Manufacturer bulletinPDF · 1 page · 574 KB

    GAF TAB-R 2017-164: Underlayment Requirements for Hips and Ridges on a Single-Plane Repair

    One-page GAF bulletin on how underlayment must be lapped over a hip when only one roof plane is being replaced, including removing end nails on the adjacent plane and re-nailing — the detail that turns a single-slope repair into work on the neighboring slope.

    GAFGAF Technical Services · 2017