    Guidance Roofing Flat Roof - Types Introduction • A roof is defined in BS 6229 as a flat roof if it has a pitch of 10 degrees or less. • A flat roof must be strong, durable and stable throughout its lifetime. It must provide adequate protection against the elements, keeping the buildings structure and interior dry. • Flat roofs have a reputation of failing early but improvements in strength, flexibility, ageing and weather resistance mean that, if built with care, using the correct materials, today’s high performance felts can have a life span of up to 20 years. Roof Types Flat roof constructions are generally classed as either ‘Cold’ or ‘Warm’ roofs depending on the position of the thermal insulation. The Cold Roof • Although not recommended today, and actually banned in Scotland, until recently cold flat roofs were fairly common. • In a cold roof the thermal insulation is laid between the joists below the structural deck. • As the insulation is not required to take any loads, quilts and other loose fill materials can be used as well as rigid insulation. Click Image for Low-Res Preview Cold Flat Roof Detail, Felt Covering £2.49 Add To Basket Includes DXF, DWG and Jpeg • Because the structural elements of a cold roof are not protected by from the heat of the sun by a layer of insulation they are liable to suffer the damaging effects of thermal movement. • Ventilation is required above the insulation in a cold roof to prevent the build up of moisture vapour in the roof void. Foundations Floors Warm Deck Roof • In a warm deck roof the insulation is positioned above the structural deck and no ventilation is required. • Throughout the course of the year the roof deck and all below it is kept at a temperature close to that of the inside of the building, therefore the roof structure is protected from extremes of hot and cold, lessening the potential for damage caused by thermal movement. Warm Flat Roof Detail, Felt Covering • A warm deck also provides added protection from the dangers of condensation as the structure is kept warm, at a temperature above dewpoint, by the insulation above it. Therefore water vapour which enters the roof structure from the room below will not have a cold surface on which to condense. NHBC recommend that this type of roof be considered as the standard form of construction. Types of Warm deck roof There are two forms of warm deck roof: • Sandwich • Inverted Warm Deck: Sandwich Roof • The sandwich warm deck roof is the most common type of flat roof. The insulation is placed below the waterproof covering and is either mechanically fixed or bitumen bonded on to the top of the deck. Inverted warm deck roof • The insulation boards in an inverted warm deck are laid over the structural deck and the waterproof covering. The insulation is secured by a layer of ballast or paving slabs to prevent wind uplift. • The waterproofing membrane has the added protection of the insulation from foot traffic and degradation caused by exposure to solar radiation. However, it may be a more difficult to locate defects in the membrane. • Proprietary systems are available now which combine the insulation and ballast layers. Flat Roof - Components Components of a Flat Roof A flat roof is a multi-layer construction typically comprising of the following elements: • Waterproof membrane with a protective covering - this should prevent water reaching the roof structure and the room below. • Thermal insulation – ensures thermal comfort is maintained inside the building and often provides support for the waterproofing membrane (warm roof). • Roof deck - provides a base for the waterproof membrane or the insulation. • Vapour control layer - helps reduce the risk of condensation. • Load bearing supportive structure - transmits the weight of the roof and any loads acting on it onto the loadbearing walls.

    What this document argues

    A scrape of a British building-regulations plan-drawing site covering flat roof types and the drainage that serves them. It works through the cold roof (insulation between the joists, ventilation required above it, and now banned in Scotland), the warm deck sandwich roof, and the inverted roof where insulation and ballast sit over the membrane, then itemises the layers of a flat roof assembly and the covering options — built-up reinforced bitumen, mastic asphalt, single ply, green roofs, metal sheet — before moving on to outlets, gutters and underground drainage.

    Why a contractor cares. The cold-versus-warm-versus-inverted comparison is a clean statement of why insulation position drives condensation risk and thermal movement. The regime is British, so take the reasoning and not the requirements.

    Why a public adjuster cares. Little directly. It defines a flat roof as 10 degrees or less under BS 6229, which does not match US low-slope convention, and it cites no US code or policy language.

    A summary written by the National Roofing Directory, not an extract. The work itself is buildingregs4plans.co.uk (United Kingdom)'s and is not reproduced here.

    Provenance · Obtained from publicly circulated copies; no ownership claimed; removal honored on request

    Every document here names its publisher. Documents were gathered from public circulation and are posted in good faith with attribution — no ownership is claimed, nothing is sold, and rights holders can have anything removed on request. Read the content notice

    More from Installation & Repair

    On the same shelf

    Manufacturer bulletinPDF · 2 pages · 174 KB

    GAF TAB-C 2015-31: Repairing Hail Damage to Granule-Surfaced Membranes

    GAF's commercial technical advisory bulletin on hail that scours granules off a granule-surfaced membrane: what to inspect for, when coating the membrane is an acceptable repair, and the Diamond Pledge guarantee question that follows a coating repair.

    GAFGAF Technical Services · 2015

    Manufacturer bulletinPDF · 2 pages · 239 KB

    GAF TAB-R-178: Mixing New and Aged Asphalt Shingles

    GAF's bulletin on whether new shingles can be used to repair an aged roof — it allows it when dimensions and exposure match, warns that a perfect color blend is "not likely," forbids trimming shingles to match, and notes aged shingles crack during repair. Central to matching disputes.

    GAFGAF Residential Consumer Services · 2025

    Manufacturer bulletinPDF · 1 page · 574 KB

    GAF TAB-R 2017-164: Underlayment Requirements for Hips and Ridges on a Single-Plane Repair

    One-page GAF bulletin on how underlayment must be lapped over a hip when only one roof plane is being replaced, including removing end nails on the adjacent plane and re-nailing — the detail that turns a single-slope repair into work on the neighboring slope.

    GAFGAF Technical Services · 2017

    Back to the full library